WiFi-500 传感器系列

 

低成本 WiFi 数据记录传感器

KEY HIGHLIGHTS

WiFi-500低成本温湿度无线数据记录传感器有多种参数可调。各设备均有数据记录、液晶显示、高低声音报警并符合IEEE 802.11b WiFi规范。支持温度和湿度数据采集,采用电池供电。

模拟输入
通道数 最大采样率
多达2路 10 S/s
传感器
温度 热电偶 RTD
所有
热敏电阻 湿度 电压
WiFi-501-TP WiFi-502
内存 电源
内存 电源
高达250,000 可充电电池


Part Number Description Qty
WiFi-501 带LCD的WiFi温度传感器,可充电电池供电;包含25 in. 微型USB连接线和壁式托架
WiFi-501-TP 内置充电电池的WiFi温度记录仪,带有LCD显示屏和可拆卸热敏电阻探头;附带25 in. Micro-USB线缆,以及固定挂钩
WiFi-502 可充电电池供电式WiFi温度和湿度数据记录传感器,集成液晶显示器;提供25英寸微型USB电缆和壁挂式安装支架

Product Reviews


4.1 / 5
Ease of Use
4.6 / 5
Value
4.1 / 5
Techincal Support
4.4 / 5

86% of new reviewers recommend this product


WiFi-501-TP
September 25, 2015
Nice Device

WE needed a temp logger for our freezers and fridges. The USB 501 worked nice. The Wifi and cloud app are great as we can not only monitor the temp levels but get warning if we need to move food before it spoils. Easy setup. Longer battery life would be nice but we'll plug them in.

  • Job Title: Food Pantry Director
  • Industry: Charity
  • Application: Monitor temp of freezers
  • From: Stony Point Reformed Presbyterian Church
  • Company Size: 1-100
  • Software Used: C++/C#/VB

  • Ease of use
  • Value
  • Techincal Support
Yes, I recommend this product!

Was this review helpful? Yes (0) / No (0)

WiFi-502
February 18, 2014
Sent back - does not work with our wireless protocol

Temperature device requires WEP or WPA(2)-PSK. We use EAP-TKIP

  • Job Title: Sen. Engr. Tech
  • From:
  • Company Size:
  • Software Used:

  • Ease of use
  • Value
  • Techincal Support
Yes, I recommend this product!

Was this review helpful? Yes (1) / No (0)

WiFi-501
February 11, 2014
User Friendly Remote Temperature Sensor

I used this temperature sensor to check the temperature of my well thru the recent abnormally cold periods that we've had in North Carolina. My well is about 150 feet from my wi-fi base with a brick wall in between. Had no trouble setting up the software, and got the measurements that I was after. I would like to see a unit with two temperature sensor inputs.

  • Job Title: Retired Electronics Engineer
  • Industry: Retired NASA
  • Application: Home Management
  • From: Lake Norman, North Carolina, USA
  • Company Size: 1-100
  • Software Used: Other

  • Ease of use
  • Value
  • Techincal Support
Yes, I recommend this product!

Was this review helpful? Yes (1) / No (0)

WiFi-502
August 08, 2013
Great Data Logger

I work in IT, we had an engineer interested in data logging various parts of the building. The setup and installation of said data loggers was easy. The EasyLog Wi-Fi software provided was straight-forward using Windows 7. From an IT perspective I highly recommend using this product.

  • Job Title: Network Technician
  • Industry: Automotive
  • From: Saginaw, MI
  • Company Size: 101-500
  • Software Used: Other

  • Ease of use
  • Value
  • Techincal Support
Yes, I recommend this product!

Was this review helpful? Yes (1) / No (0)

WiFi-502
August 01, 2013
WPA2 Enterprise Support missing

As other reviewers have stated, the lack of data download via USB seems to be a mysterious omission. One would think that, as a primary way to recharge and configure the device, downloading the acquired data via USB is a natural. My other gripe is that WPA2 Enterprise (corporate level) security is not yet supported, making it useless to me. I was assured by Tech Support that the software update would be available to me by September. We shall wait and see. Other than those two items, it seems to be well-built and accurate. I promise to update this review when I am able to integrate it into my cleanroom monitoing system.

  • Job Title: Engineer Associate
  • Industry: Education/Research
  • Application: Cleanroom environment monitoring
  • From: Auburn, AL, USA
  • Company Size: 5000+
  • Software Used: NI LabVIEW

  • Ease of use
  • Value
  • Techincal Support
Yes, I recommend this product!

Was this review helpful? Yes (2) / No (0)

WiFi-502
July 26, 2013
easy to use

we have installed 12 devices in our factory and very easy to monitor temperature & humidity. the data record easy to manipulate for presentations.

  • Job Title: Manufacturing engineering manager
  • Industry: militar
  • Application: RF microwave
  • From: West Palm Beach, FL, USA
  • Company Size: 101-500
  • Software Used: TracerDAQ

  • Ease of use
  • Value
  • Techincal Support
Yes, I recommend this product!

Was this review helpful? Yes (1) / No (0)

WiFi-502
March 26, 2013
Works fairly well - no data access via usb...

Wifi hooks up easily the first time but I've experienced some issues when it looses a connection to the AP or also when trying to use in an environment where there are multiple AP's. Also, there is no way to download data via USB, this is particularly painful when you can't get the wifi device to re-associate with your AP and you have to go through the initial setup process, what ever data is on the device goes out the window.

  • Job Title: IT Manager
  • Industry: 3rd Party Logistics / Warehousing
  • Application: monitoring temperatures in our warehouse
  • From: Salt Lake City, UT, USA
  • Company Size: 1-100
  • Software Used: TracerDAQ

  • Ease of use
  • Value
  • Techincal Support
Yes, I recommend this product!

Was this review helpful? Yes (4) / No (0)




We are looking for a WIFI temperature logger that can operate attached to a rotary dryer. The location is in Vietnam so ambient external temperatures are quite high 30-40c and the dryer is rotating. We want to measure internal dryer temperature at least 4

  • Job Title: Managing Director
  • Industry: Coffee
  • Application:
65 months ago
Buddy Ho Chi Minh City, Vietnam


Answers

Assuming that you don't exceed the temperature limits of the unit, and that there is sufficient signal strength, it should do the job

58 months ago
Pap37

Was this answer helpful? Yes (1) / No (0)

The WIFI loggers are not rated for mechanical shock, so if you intend to allow them to rotate along with the dryer drum, you should test that environmental aspect. The number of loggers supported will depend on the capacity of the router the loggers are connected to. A mid-range quality router is able to accommodate approximately 70 loggers before seeing dropouts. The provided software will handle the loggers local to one router, but will not aggregate the data from your multiple sites.

65 months ago
MeasurementComputing

Was this answer helpful? Yes (1) / No (0)

We are looking into using this logger as an OEM part in our instrument. The main application is written in LabVIEW. Do you provide a LabVIEW API that will enable us to programmatically set logging parameters, start/stop logging and retrieve logged data?

  • Job Title:
  • Industry:
  • Application:
67 months ago
Cepera Boston, MA, USA


Answers

The WiFi-500 Series, which includes the WiFi-501-TP, are not compatible with LabVIEW. Currently the software that is packaged with these devices is the only form of software support that is provided. We do have other temperature products, such as a wireless device that uses 802.15 (PAN) that is supported by our ULx for NI LabVIEW drivers. Please contact Sales Engineering at 1-800-234-4232 x3 to discuss available opportunities for an OEM relationship or to discuss your application further.

67 months ago
MeasurementComputing

Was this answer helpful? Yes (0) / No (1)

Hello Non-stop data logging is very inconvenient. Is there any chance to control logging with a device button (i.e. press for X seconds until something like ON/OFF mesage appears on the screen). If I want to use the logger (being unused for several days) I have to delete thousands of logs. But after I run the software, I have to wait till all data is sent do PC to remove readings from a device. Of course I may set reading time to 12 hours, but it's not a convenient solution for me.

  • Job Title: Data Center Specialist
  • Industry:
  • Application:
43 months ago
kotfilemon Poland


Answers

Hello - Historically data loggers were targeted towards remote long term data collection. And as such, these loggers were not designed to be configurable to stop logging after a short time duration. What may meet your needs better is a data acquisition (DAQ) device such as the USB-2408. It requires a local PC to run (not well suited for remote deployment), but the available software (such as DAQami) is more flexible. Note that DAQ hardware does not have sensors built in, so you would need to procure the desired sensors (temperature, humidity).

43 months ago
Measurement Computing

Was this answer helpful? Yes (1) / No (0)

Is it possible to do SNMP protocol support?

  • Job Title: Data Center Specjalist
  • Industry:
  • Application:
44 months ago
kotfilemon


Answers

Hello - SNMP protocol is not possible. The communication to the WiFi sensor hardware is via the provided high-level WiFi Sensor Software only.

44 months ago
Measurement Computing

Was this answer helpful? Yes (0) / No (0)

Does the unit come with certification of calibration? Can the unit be calibrated and by whom?

  • Job Title: ELECTRONIC ENGINEERING MANAGER
  • Industry: AEROSPACE
  • Application: CLEAN ROOM TEMP/HUMIDITY MONITORING
61 months ago
jbrentano VALHALLA, NY


Answers

No cal. cert. in the one I purchased.

58 months ago
redman25

Was this answer helpful? Yes (0) / No (1)

No re-calibration is possible for this model. Also, MCC does not offer calibration certificates for this model. It is warranted to meet published specs for 1 year. You could identify a 3rd party facility, and send the unit out to them. They would not calibrate it, but perhaps they could verify the accuracy.

61 months ago
MeasurementComputing

Was this answer helpful? Yes (0) / No (0)

Included Software


Product Manuals


WiFi-501
document
 
WiFi-501-TP
document
 
WiFi-502
document
 

 

Product Videos


MCC Video Library
video
 

 

Programming Example Downloads      download

1 Year Warranty

1年保修

所有产品均有一年保修,请放心购买。

30 Day Money Back Guarantee

质量
保证

我们致力于设计和制造高于用户期望的数据采集(DAQ)产品。

Live Help

在线帮助

不知道哪款产品最适合您的应用?我们的销售工程师会帮助您。