DT9812 系列

低通道数多功能USB数据采集设备

KEY HIGHLIGHTS

DT9812系列USB数据采集设备提供模拟输入通道、模拟输出通道、数字I/O。各设备均有坚固的外壳保护。我们同样提供OEM版本以供嵌入式应用。

模拟输入
通道数 分辨率 最大采样率
8 12-位 高达 100 kS/s
采样 范围 隔离
复采样 ±10 V, ±5 V, ±2.5 V, ±1.25 V
模拟输出
通道数 分辨率 速度
2 12-位 高达 75 kS/s
数字I/O
通道数 计数器/定时器 编码器
16 1
软件 电源
操作系统支持 驱动 电源
Windows® Open Layers® SW Suite 总线供电


Part Number Description
DT9812-10V
SKU: 6069-410-131
Low Cost USB Data Acquisition (DAQ) Module, 12-bit, 50kHz, 8 AI, 2 AO, 16 DIO, 1 C/T
DT9812-10V-OEM
SKU: 6069-410-132
Low Cost USB Data Acquisition (DAQ) Board, 12-bit, 50kHz, 8 AI, 2 AO, 16 DIO, 1 C/T, No Enclosure
Accessories & Cables
ECON DIN RAIL KIT
SKU: 6069-240-008
Kit for mounting ECON Series USB modules to a DIN rail. Horizontal or vertical mounting fits any application. Includes mounting clips, screws, and instructions. Rail not included.

Product Reviews




Hello, could you please give more detail about the packaging used for the shipping of the DT9812-10V-OEM ? Does It come in a card box ? what is the size of the BOX ? It is always the same packaging whatever the quantity I order ?

  • Job Title: Project Manager
  • Industry: Medical
  • Application: Cells therapy
18 months ago
Omarti Lausanne


Answers

Yes, the DT9812-10V-OEM ships inside a cardboard box. The size of the container is as follows: 23.6 X 20.7 X 3.5 Each product ordered will ship in its own shipping box.

18 months ago
Measurement Computing

Was this answer helpful? Yes (1) / No (0)

Hello, I am using more than one DT9812 at the same time and I would like to be able to identify witch module is what. Is it possible to set a name or a specific ID /serial that can be used for that ? I would like that the number or name is stored inside the DT9812 that I can detect it even if I change the computer. Thanks Olivier

  • Job Title: Project Manager
  • Industry: Medical
  • Application: laboratory device
49 months ago
Oliver Switzerland


Answers

Each Data Translation module contains a unique board ID, which can be found in Windows’ (legacy) Control Panel via the Open Layers Control Panel applet. A user can also determine the module’s board ID when developing a custom application with Data Translation’s OpenLayers for .NET (use the GetHardwareInfo method to retrieve the device’s BoardID). Note that while the BoardID is unique, it does not correlate to the S/N labeled on module. The BoardID does seem well suited to your stated need, as it will travel with the module to another computer. For sake of completeness, while not suitable for your stated need, the following info on DeviceName is provided: When a Data Translation module is connected to a Windows system, the module is assigned a ‘DT-Open Layer Name’ that can be found in Windows’ (legacy) Control Panel via the Open Layers Control Panel applet. The first DT9812-10V module connected will be assigned ‘DT9812(00)’. Additional modules of the same model will have an incremented name, i.e. ‘DT9812(01)’ for the second module. A user can also determine the module’s name when developing a custom application with Data Translation’s OpenLayers for .NET (use the Device class to retrieve the ‘DeviceName’ property). Note, if the DT9812-10V module is disconnected and then connected to a different system, the module’s assigned name will then depend on what order the module was connected to the system and whether or not the module was previously connected to the system. Information for each module’s connection is retained in the system’s Registry (as is the device’s BoardID). Lastly, in the DT9812 Series User’s Manual, the ‘Changing the Name of a Module’ section of chapter 2 discusses how to access the Open Layers Control Panel applet and how to edit the board’s name.

49 months ago
Measurement Computing

Was this answer helpful? Yes (1) / No (0)

Hello,

  • Job Title: Project manager
  • Industry: Medical
  • Application: Medica
54 months ago
Oliver Switzerland


Answers

Regrettably, we do not have a CAD model for the DT9812-10V-OEM. However, we do have a dimensional drawing that can be downloaded from here: https://www.mccdaq.com/pdfs/drawing

54 months ago
Measurement Computing

Was this answer helpful? Yes (1) / No (0)

Hello, I am using the DT9812. I would like to be able to follow which DT9812 is in which device to be able to know which device is impacted in case of failure. Where can I find the trackability lot number? Is it possible to read it in the firmware?

  • Job Title: project manager
  • Industry: Medical device
  • Application: cells therapy
36 months ago
OMa Switzerland


Answers

Each Data Translation device is assigned a unique device ID (also known as board ID). This ID is easily found via the Open Layers Control Panel applet, on a target system with the Data Translation OMNI software (Open Layers) already installed. If multiple DT devices, of the same model, are connected to the same system, then the end-user should access the Open Layers Control Panel applet to review the device ID, after each connection. For programmers using the DT-Open Layers Win32 SDK, the sixth argument in the olDaGetHardwareInfo() function returns the DT device's serial number, as a hex value. Converted to a decimal value, the serial number matches the ID number listed in the Open Layers Control Panel applet. Please review the DASDK.chm Help file located in folder: 'C:\Program Files (x86)\Data Translation\Win32\SDK\Documentation'. For programmers using DT-Open Layers for .NET, the Device.GetHardwareInfo method returns the 'BoardID' value. Please reference the DT-Open Layers for .NET Class Library User’s Manual. https://www.mccdaq.com/PDFs/Manuals/UMOpenLayers.pdf

36 months ago
Measurement Computing

Was this answer helpful? Yes (1) / No (0)

Regarding the OEM PCB, what is the purpose of the metallic ring around the mounting hole near the USB connector? It is connected to the shield pin of the USB. Do we need to connect this metallic ring to the shielding of the device, or it is OK to do it only by the USB connector? Thanks

  • Job Title: Project Manager
  • Industry: Medical Device
  • Application: laboratory device
44 months ago
Olivier Switzerland


Answers

That mounting hole with the metallic ring, on the OEM model, is labeled TH1. TH1 has a direct connection to the chassis ground of the DAQ, and is also connected to the USB shell. Energy shunted to the DAQ’s chassis ground would normally go to earth ground via the USB shell/cable, but we highly recommend that you also connecting TH1 to your earth/chassis ground.

44 months ago
Measurement Computing

Was this answer helpful? Yes (2) / No (0)

Included Software


  • DT-Open Layers for .NET a simple to use, yet powerful native .NET class library for developing test and measurement applications in Microsoft Visual Studio®
  • LV-LinkTM a library of VIs (Virtual Instruments) that enable LabVIEW™ programmers to access the data acquisition features of DT-Open Layers-compliant USB and PCI devices
  • DAQ Adaptor for MATLAB® MATLAB® from The MathWorks® is a software environment and programming language used for data acquisition, data analysis, measurement automation, and application development
  • QuickDAQ Base Package Data Logging Software

Optional Software


  • QuickDAQ Data Logging and FFT Analysis Software

 

 

Programming Example Downloads      download

Product Videos


MCC Video Library
video
 
1 Year Warranty

1年保修

所有产品均有一年保修,请放心购买。

30 Day Money Back Guarantee

质量
保证

我们致力于设计和制造高于用户期望的数据采集(DAQ)产品。

Live Help

在线帮助

不知道哪款产品最适合您的应用?我们的销售工程师会帮助您。