PCI-DAS6402/16

 

64通道、16位、200 kS/s 多功能板卡

KEY HIGHLIGHTS

The PCI-DAS6402/16 data acquisition (DAQ) board provides a higher channel count compared to other 16-bit multifunction devices. Features include analog input, digital I/O, one counter, and two analog outputs capable of arbitrary waveform generation.

模拟输入
通道数 分辨率 最大采样率
64 单端/32 差分 16-位 200 kS/s
采样 范围 隔离
复采样 ±10 V, ±5 V, ±2.5 V, ±1.25 V, 0-10 V, 0-5 V, 0-2.5 V, 0-1.25 V
模拟输出
通道数 分辨率 速度
2 16-位 100 kS/s
数字 I/O
通道数 计数器/定时器 编码器
32 1/—
软件 电源
操作系统支持 驱动 电源
Windows® Universal Library™ SW Suite 总线供电


Part Number Description Qty
PCI-DAS6402/16 基于PCI的64路单端或32路差分16位模拟输入板,采样率高达200 kS/s,集成2路16位模拟输出、32位数字I/O、1个16位减法计数器
Signal Conditioning Options
ISO-5B30-01 Analog isolation module, voltage/current input, 4 Hz ±10 mV input, ±5 V output
close More Options...    
ISO-5B30-02 Analog isolation module, voltage/current input, ±50 mV input, ±5 V output
ISO-5B30-03 Analog isolation module, voltage/current input, ±100 mV input, ±5 V output
ISO-5B30-04 Analog isolation module, voltage/current input, ±10 mV input, 0 to 5 V output
ISO-5B30-05 Analog isolation module, voltage/current input, ±50 mV input, 0 to 5 V output
ISO-5B30-06 Analog isolation module, voltage/current input, ±100 mV input, 0 to 5 V output
ISO-5B31-01 Analog isolation module, voltage/current input, ±1 V input, ±5 V output
ISO-5B31-02 Analog isolation module, voltage/current input, ±5 V input, ±5 V output
ISO-5B31-03 Analog isolation module, voltage/current input, ±10 V input, ±5 V output
ISO-5B31-04 Analog isolation module, voltage/current input, ±1 V input, 0 to 5 V output
ISO-5B31-05 Analog isolation module, voltage/current input, ±5 V input, 0 to 5 V output
ISO-5B31-06 Analog isolation module, voltage/current input, ±10 V input, 0 to 5 V output
ISO-5B31-07 Analog isolation module, voltage/current input, ±20 V input, ±5 V output
ISO-5B31-08 Analog isolation module, voltage/current input, ±20 V input, 0 to 5 V output
ISO-5B31-09 Analog isolation module, voltage/current input, ±40 V input to ±5 V output
ISO-5B31-10 Analog isolation module, voltage/current input, ±40 V input, 0 to 5 V output
ISO-5B32-01 Analog isolation module, voltage/current input, 4 to 20 mA input, 0 to 5 V output
ISO-5B32-02 Analog isolation module, voltage/current input, 0 to 20 mA input, 0 to 5 V output
ISO-5B33-01 Analog isolation module, true RMS input, 0 to 100 mV input, 0 to 5 V output
ISO-5B33-03 Analog isolation module, true RMS input, 0 to 10 V input, 4 to 20 mA output
ISO-5B33-05 Analog isolation module, true RMS input, 0 to 300 V input, 0 to 5 V output
ISO-5B33-06 Analog isolation module, true RMS input, 0 to 1 A input, 0 to 5 V output
ISO-5B34-01 Analog isolation module, linearized 2- or 3-wire RTD input, 100 Ohm platinum, -100 to +100 °C input, 0 to 5 V output
ISO-5B34-02 Analog isolation module, linearized 2- or 3-wire RTD input, 100 Ohm platinum, 0 to 100 °C input, 0 to 5 V output
ISO-5B34-03 Analog isolation module, linearized 2- or 3-wire RTD input, 100 Ohm platinum, 0 to 200 °C input, 0 to 5 V output
ISO-5B34-04 Analog isolation module, linearized 2- or 3-wire RTD input, 100 Ohm platinum, 0 to 600 °C input, 0 to 5 V output
ISO-5B34-C-01 Analog isolation module, linearized 2- or 3-wire RTD input, 10 Ohm copper (18 °C), 0 to 120 °C input, 0 to 5 V output
ISO-5B34-C-02 Analog isolation module, linearized 2- or 3-wire RTD input, 10 Ohm copper (25 °C), 0 to 120 °C input, 0 to 5 V output
ISO-5B34-N-01 Analog isolation module, linearized 2- or 3-wire RTD input, 120 Ohm nickel, 0 to 300 °C input, 0 to 5 V output
ISO-5B35-01 Analog isolation module, linearized 4-wire RTD input, 100 Ohm platinum, ±100 °C input, 0 to 5 V output
ISO-5B36-02 Analog isolation module, potentiometer input, 0 to 500 Ohm input, 0 to +5 V output
ISO-5B37-B Analog isolation module, non-linearized, B-type thermocouple input, 0 to 1800 °C input, 0 to 5 V output
ISO-5B37-C Analog isolation module, non-linearized, C-type thermocouple input, 350 to 1300 °C input, 0 to +5 V output
ISO-5B37-E Analog isolation module, non-linearized, E-type thermocouple input, 0 to 900 °C input, 0 to 5 V ouput
ISO-5B37-J Analog isolation module, non-linearized, J-type thermocouple input, -100 to +760 °C input, 0 to 5 V output
ISO-5B37-K Analog isolation module, non-linearized, K-type thermocouple input, -100 to +760 °C input, 0 to 5 V output
ISO-5B37-N Analog isolation module, non-linearized, N-type thermocouple input, -100 to +1300 °C input, 0 to 5 V output
ISO-5B37-R Analog isolation module, non-linearized, R-type thermocouple input, 0 to 1750 °C input, 0 to 5 V output
ISO-5B37-S Analog isolation module, non-linearized, S-type thermocouple input, 0 to 1750 °C input, 0 to 5 V output
ISO-5B37-T03 Analog isolation module, non-linearized, T-type thermocouple input, -100 to +400 °C input, 0 to 5 V output
ISO-5B38-01 Analog isolation module, strain gage input (10 kHz), full bridge (3.333 V at 3 mV/V sensitivity), 100 to 10 kOhm, -5 to +5 V output
ISO-5B38-02 Analog isolation module, strain gage input (10 kHz), full bridge (10.0 V at 3 mV/V sensitivity), 300 to 10 kOhm, -5 to +5 V output
ISO-5B38-03 Analog isolation module, strain gage input (10 kHz), half bridge (3.333 V at 3 mV/V sensitivity), 100 to 10 kOhm, -5 to 5 V output
ISO-5B38-04 Analog isolation module, strain gage input (10 kHz), half bridge (10.0 V at 3 mV/V sensitivity), 300 to 10 kOhm, -5 to +5 V output
ISO-5B38-05 Analog isolation module, strain gage input (10 kHz), full bridge (3.333 V at 2 mV/V sensitivity), 300 to 10 kOhm, -5 to +5 V output
ISO-5B38-06 Analog isolation module, strain gage input (10 kHz), full bridge (10.0 V at 10 mV/V sensitivity), 100 to 10 kOhm, -5 to +5 V output
ISO-5B38-07 Analog isolation module, strain gage input (10 kHz), full bridge (10.0 V at 10 mV/V sensitivity), 300 to 10 kOhm, -5 to +5 V output
ISO-5B39-01 Analog isolation module, current output, (400 Hz), 0 to 5 V input, 4 to 20 mA output
ISO-5B39-02 Analog isolation module, current output, (400 Hz), ±5 V input, 4 to 20 mA output
ISO-5B39-03 Analog isolation module, current output, (400 Hz), 0 to 5 V input, 0 to 20 mA output
ISO-5B39-04 Analog isolation module, current output, (400 Hz), ±5 V input, 0 to 20 mA output
ISO-5B39-07 Analog isolation module, current output, (400 Hz), ±10 V input, ±20 mA output
ISO-5B40-01 Analog isolation module, voltage input (10 kHz), ±10 mV input, ±5 V output
ISO-5B40-02 Analog isolation module, voltage input (10 kHz), ±50 mV input, ±5 V output
ISO-5B40-03 Analog isolation module, voltage input (10 kHz), ±100 mV input, ±5 V output
ISO-5B40-04 Analog isolation module, voltage input (10 kHz), ±10 mV input, 0 to 5 V output
ISO-5B40-05 Analog isolation module, voltage input (10 kHz), ±50 mV input, 0 to 5 V output
ISO-5B40-06 Analog isolation module, voltage input (10 kHz), ±100 mV input, 0 to 5 V output
ISO-5B41-01 Analog isolation module, voltage input (10 kHz), ±1 V input, ±5 V output
ISO-5B41-02 Analog isolation module, voltage input (10 kHz), ±5 V input, ±5 V output
ISO-5B41-03 Analog isolation module, voltage input (10 kHz), ±10 V input, ±5 V output
ISO-5B41-04 Analog isolation module, voltage input (10 kHz), ±1 V input, 0 to 5 V output
ISO-5B41-05 Analog isolation module, voltage input (10 kHz), ±5 V input, 0 to 5 V output
ISO-5B41-06 Analog isolation module, voltage input (10 kHz), ±10 V input, 0 to 5 V output
ISO-5B41-07 Analog isolation module, voltage input (10 kHz), high-speed, wide band, ±20 V input, ±5 V output
ISO-5B41-08 Analog isolation module, voltage input (10 kHz), ±20 V input, 0 to 5 V output
ISO-5B41-09 Analog isolation module, voltage input (10 kHz), ±40 V input, ±5 V output
ISO-5B41-10 Analog isolation module, voltage input (10 kHz), ±40 V input, 0 to 5 V output
ISO-5B42-01 Analog isolation module, 2-wire transmitter interface, 4 mA to 20 mA input, 1 to 5 V output
ISO-5B43-02 Analog isolation module, general purpose input (1 kHz) with DC excitation, ±2 V input, ±5 V output
ISO-5B43-05 Analog isolation module, general purpose input (1 kHz) with DC excitation, ±5 V input, ±5 V output
ISO-5B43-10 Analog isolation module, general purpose input (1 kHz) with DC excitation, ±10 V input, ±5 V output
ISO-5B45-01 Analog isolation module, frequency input, 0 to 500 Hz input, 0 to 5 V output
ISO-5B45-02 Analog isolation module, frequency input, 0 to 1 kHz input, 0 to 5 V output
ISO-5B45-03 Analog isolation module, frequency input, 0 to 3 kHz input, 0 to 5 V output
ISO-5B45-04 Analog isolation module, frequency input, 0 to 5 kHz input, 0 to 5 V output
ISO-5B45-05 Analog isolation module, frequency input, 0 to 10 kHz input, 0 to 5 V output
ISO-5B45-06 Analog isolation module, frequency input, 0 to 25 kHz input, 0 to 5 V output
ISO-5B45-07 Analog isolation module, frequency input, 0 to 50 kHz input, 0 to 5 V output
ISO-5B45-08 Analog isolation module, frequency input, 0 to 100 kHz input, 0 to 5 V output
ISO-5B47-B-11 Analog isolation module, linearized B-type thermocouple input, 500 to 1800 °C input, 0 to 5 V output
ISO-5B47-E-08 Analog isolation module, linearized E-type thermocouple input, 0 to 100 °C input, 0 to 5 V output
ISO-5B47-J-01 Analog isolation module, linearized J-type thermocouple input, 32 to 760 °C input, 0 to 5 V output
ISO-5B47-J-02 Analog isolation module, linearized J-type thermocouple input, -100 to +300 °C input, 0 to 5 V output
ISO-5B47-J-03 Analog isolation module, linearized J-type thermocouple input, 0 to 500 °C input, 0 to 5 V output
ISO-5B47-K-04 Analog isolation module, linearized K-type thermocouple input, 0 to 1000 °C input, 0 to 5 V output
ISO-5B47-K-05 Analog isolation module, linearized K-type thermocouple input, 0 to 500 °C input, 0 to 5 V output
ISO-5B47-K-13 Analog isolation module, linearized K-type thermocouple input, -100 to +1350 °C input, 0 to 5 V output
ISO-5B47-K-14 Analog isolation module, linearized K-type thermocouple input, 0 to 1200 °C input, 0 to 5 V output
ISO-5B47-R-09 Analog isolation module, linearized R-type thermocouple input, 500 to 1750 °C input, 0 to 5 V output
ISO-5B47-S-10 Analog isolation module, linearized S-type thermocouple input, 500 to 1750 °C input, 0 to 5 V output
ISO-5B47-T-06 Analog isolation module, linearized T-type thermocouple input, -100 to +400 °C input, 0 to 5 V output
ISO-5B47-T07 Analog isolation module, linearized T-type thermocouple input, 0 to 200 °C input, 0 to 5 V output
ISO-5B-DS Pass through module - no isolation or conditioning - input direct to output
ISO-5B49-01 Analog isolation module, voltage output (400 Hz), 0 to 5 V input, ±5 V output
close More Options...    
ISO-5B49-02 Analog isolation module, voltage output (400 Hz) ±5 V input, ±5 V output
ISO-5B49-03 Analog isolation module, voltage output (400 Hz) ±5 V input, 0 to 5 V output
ISO-5B49-04 Analog isolation module, voltage output (400 Hz) 0 to 10 V input, ±10 V output
ISO-5B49-05 Analog isolation module, voltage output (400 Hz) ±10 V input, ±10 V output
ISO-5B49-06 Analog isolation module, voltage output (400 Hz) ±10 V input, 0 to 10 V output
ISO-5B49-07 Analog isolation module, voltage output (400 Hz) ±5 V input, ±10 V output
ISO-DA02/P 5B module backplane for 50-pin PCI-DDA02 and 100-Pin PCI-DAS Series, 2-channel
   
ISO-RACK16/P Isolation module backplane (ISO-5B Series modules) for CIO-DAS6400 and PCI-DAS6400, 1600, 1200, and 1000 series A/D boards, 16-channel
close More Options...     User's Manual User Manual   
SSR-IDC-05 Solid-state relay module, single, DC sense, 3 to 32 VDC
close More Options...     Data Sheet Data Sheet   
SSR-IAC-05 Solid-state relay module, single, AC sense, 90 to 140 VAC
Data Sheet Data Sheet   
SSR-IAC-05A Solid-state relay module, single, AC sense, 180 to 280 VAC/VDC
Data Sheet Data Sheet   
SSR-IDC-05NP Solid-state relay module, single, DC sense, 10 to 32 VDC non-polarized digital inputs
Data Sheet Data Sheet   
SSR-OAC-05 Solid-state relay module, single, AC switch, 24 to 140 VAC, 3.5 A @ 120 VAC
Data Sheet Data Sheet   
SSR-OAC-05A Solid-state relay module, single, AC switch, 24 to 280 VAC, 3.5 A @ 240 VAC
Data Sheet Data Sheet   
SSR-ODC-05 Solid-state relay module, single, DC switch, 1 to 60 VDC @ 3.5 A
Data Sheet Data Sheet   
SSR-ODC-05A Solid-state relay module, single, DC switch, 4 to 200 VDC, 1 A
Data Sheet Data Sheet   
SSR-RACK24 Solid-state relay backplane (Gordos/OPTO-22 type relays), 24-channel
close More Options...     User's Manual User Manual   
Accessories & Cables
BNC-16SE BNC connector box, 16-channel single-ended, for DAS16/6400/1600/1200/1000
More Options...
BNC-16DI BNC connector box, 8-channel differential, for DAS16/6400/1600/1200/1000
C100FF-1 Cable, 50-conductor ribbon, 100-pin, high-density to two 50-pin IDC, 1 ft.
More Options...
C100FF-10 Cable, 50-conductor ribbon, 100-pin, high-density to two 50-pin IDC, 10 ft.
C100FF-15 Cable, 50-conductor ribbon, 100-pin, high-density to two 50-pin IDC, 15 ft.
C100FF-2 Cable, 50-conductor ribbon, 100-pin, high-density to two 50-pin IDC, 2 ft.
C100FF-3 Cable, 50-conductor ribbon, 100-pin, high-density to two 50-pin IDC, 3 ft.
C100FF-4 Cable, 50-conductor ribbon, 100-pin, high-density to two 50-pin IDC, 4 ft.
C100FF-5 Cable, 50-conductor ribbon, 100-pin, high-density to two 50-pin IDC, 5 ft.
SCB-50 Signal connection box, two independent (side-by-side) sets of 50 screw terminals, each connected one-to-one to a 50-pin header for ribbon cable mating
More Options...
CIO-MINI50 Universal screw-terminal board, 50-pin (view dimensional drawing)
CIO-TERM100 Universal screw-terminal board, 100 terminals, for use with high-density digital I/O boards, positions for pull-up resistors (view dimensional drawing)
Software
DASYLab® LITE 基于图标的数据采集、图形、控制和分析软件
More Options...
DASYLab® BASIC 基于图标的数据采集、图形、控制和分析软件
DASYLab® FULL 基于图标的数据采集、图形、控制和分析软件
DASYLab® PRO 基于图标的数据采集、图形、控制和分析软件
DASYLab® RUNTIME 基于图标的数据采集、图形、控制和分析软件
TracerDAQ® Pro 开箱即用的虚拟仪器套件,集成带状图、示波器、函数发生器和速率发生器 – 专业版
查看价格请先 录入信息创建账户

Product Reviews


5 / 5
Ease of Use
4 / 5
Value
3 / 5
Techincal Support
2 / 5

100% of new reviewers recommend this product


PCI-DAS6402/16
December 13, 2013
Solid Product

This card is very reliable, we have used many of these cards over a period of years. It is particularly valuable because it has so many channels and a wide variety of input ranges.

  • Job Title: Lead Engineer
  • Industry: Entertainment
  • Application: Motion Control
  • From: Los Angeles
  • Company Size: 1-100
  • Software Used: C/C++

  • Ease of use
  • Value
  • Techincal Support
Yes, I recommend this product!

Was this review helpful? Yes (0) / No (0)




Could you please confirm if the PCI slot in the chassis needs to be the common 32Bit or the very rare 64Bit version? thank you

  • Job Title: Systems Administator
  • Industry:
  • Application:
45 months ago
MCWK72 Oxford, UK


Answers

The PCI-DAS6402/16 DAQ board is compatible with the 5 volt 32 bit PCI bus. However, if you only have a 5 volt 64 bit PCI slot available the PCI-DAS6402/16 will work in the 5 volt 64 bit slot as well.

45 months ago
Measurement Computing

Was this answer helpful? Yes (1) / No (0)

We're measuring 5dc, but the voltage is suplied over an 10k resistor. The problem is, that the voltage is floating from 0 until 4 volts. What is the problem

  • Job Title: Technician
  • Industry: Electronics for industry
  • Application: Test system
65 months ago
bertbro Germany


Answers

10 K is still relatively low with respect to the high input impedance of this A/D model. Make sure your signal source is also referenced to earth/PC ground. Also the issue may be in the cable or wiring – verify that you are on the correct pins, and that your 100 pin cable is inserted correctly/fully into the back of the board. You could also try shorting the input and/or using a battery instead of your signal. If this advice does not solve it, the front-end circuit of the board may require repair.

65 months ago
Measurement Computing

Was this answer helpful? Yes (0) / No (0)

My last post was this. Hello. I have a PCI-DAS6402/16 install in a windows 7 service pack 1, 32 bits. And my matlab is 2014a. My board is reconized by Instacal 6.35, but when want connection with matlab I can not ... %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% I've already changed my Matlab code: clear all; ai = analoginput('mcc',0); %(I recibe the error on this line AGAIN) Error using analoginput (line 142) Failure to find the requested data adquisition device: mcc. I wonder if it´s beacuse my O.S win 7, 32 bits. In Instacal this board appeares like: PCI Expansion (Bus 4) Board#0 - PCI-DAS6402/16 (dev#0). Also I probe with this codes: ai = analoginput('mcc',0); ai = analoginput('mcc',4); ai = analoginput('mcc','Dev0'); ai = analoginput('mcc','Dev4'); But it still doesn´t work . Please...

  • Job Title: Interface 2
  • Industry:
  • Application:
66 months ago
Fanny


Answers

Thank so much for your help. The problem was fixed. Thanks a lot.

66 months ago
fanny

Was this answer helpful? Yes (0) / No (0)

ai = analoginput('mcc',0); is correct in your case, since your logical Board# in InstaCal is 0. The O/S being Win7-32 is not a concern. If InstaCal’s analog test runs correctly, then the MCC-provided portion of the driver is operating correctly. When a application program does not find the DAQ device, when InstaCal does find it, the following 2 are the known causes: 1) Your hard drive may have multiple copies of the driver file named CBW32.DLL. Search the entire hard drive, including hidden folders, and delete all copies except the one in: C:\Program Files\Measurement Computing\DAQ 2) Your hard drive may have multiple copies of CB.CFG due to Win7 O/S’s Virtual Store. Search the entire hard drive, including hidden folders. The valid file should be located in: C:\ProgramData\Measurement Computing\DAQ Windows may be put backup of the file in: C:\Users\YourUserAccountName\AppData\Local\VirtualStore\ProgramData\Measurement Computing\DAQ Delete all copies, and then re-run InstaCal. InstaCal will make a new CB.CFG. Confirm it is in (or move it to) the location it should be in.

66 months ago
Measurement Computing

Was this answer helpful? Yes (2) / No (0)

Hello. I have a PCI-DAS6402/16 install in a windows 7 service pack 1, 32 bits. And my matlab is 2014a. My board is reconized by Instacal 6.35, but when want connection with matlab I can not. I´m using the follow code for this: clear all; ai = analoginput('mmc',1); %(I recibe the error on this line) Is like the object can not be created because Matlab does not find the board. Please, I´d appreciate your help.

  • Job Title: Interface
  • Industry:
  • Application:
66 months ago
Fanny


Answers

The most likely cause is that your DAQ device’s board number is 0 in InstaCal, but you are referencing 1 in MATLAB. See the FAQ at the following link: http://kb.mccdaq.com/KnowledgebaseArticle50495.aspx If the board numbers match, then the issue could be caused by duplicate CBW32.DLL files on the hard drive, per the following FAQ: http://kb.mccdaq.com/KnowledgebaseArticle50403.aspx

66 months ago
Measurement Computing

Was this answer helpful? Yes (0) / No (0)

Hello, We are experiencing a problem with the card “PCI DAS 6402/16” in our machine. Now we want to check this card separately by disconnecting the card from the machine. We tried to install the software “MCC DAQ” on another computer and then we insert t

  • Job Title:
  • Industry:
  • Application:
78 months ago
Bilal Bergen, Norway


Answers

Yes, this PCI model is still supported under WinXP in our latest InstaCal version (6.31). Once XP’s hardware wizard finds the board and adds it to the device manager, then launch InstaCal and run either or both of the analog tests. Instructions on how to loopback on-board signals will be displayed in InstaCal.

78 months ago
MeasurementComputing

Was this answer helpful? Yes (0) / No (0)

I need to run two PCI-DAS6402/16 cards in the same computer. How do I do this? Is there an application note that addresses doing this?

  • Job Title: Engineer
  • Industry:
  • Application: Balloon project
86 months ago
BGCarkhuff JHU-APL


Answers

For Windows, InstaCal/UL supports multiple boards of the same model. Each has its own logical board # (0, 1, etc.) and you reference the board you wish to control via its board #. You mentioned Linux … for this PCI board there is a third party driver, though you would have to consult its source code or developer to see if provisions were made to handle multiple boards. No doubt it can be done, since each board is in a different number PCI slot, and the slot number is the way two identical boards are ultimately differentiated between.

86 months ago
MeasurementComputing

Was this answer helpful? Yes (0) / No (0)

Included Software


  • TracerDAQ® for acquiring and displaying data and generating signals
  • InstaCalTM software utility for installing, configuration, and testing
  • Universal Library includes support for Visual Studio® and Visual Studio®.NET, including examples for Visual C++®, Visual C#®, and Visual Basic®.NET
  • ULx for NI LabVIEWTM Library of VIs and example programs to speed your NI LabVIEW development

Optional Software


  • DASYLab®2020 Software lets you interactively develop PC-based data acquisition applications by simply attaching functional icons
  • TracerDAQ®Pro - Out-of-the-box virtual instrument suite with strip chart, oscilloscope, function generator, and rate generator – professional version
  • MATLAB® Support for MCC Products - Software Environment for Data Acquisition, Data Analysis, and Application Development

Product Manuals


PCI-DAS6402/16
document
 

 

Quick Start Guide


DASYLab® LITE
QS-DASYLab-MCCDRV.pdf
 
ULx for NI LabVIEW™
QS ULx for NI LabVIEW.pdf
 

 

 

 

Programming Example Downloads      download

Product Videos


MCC Video Library
video
 
1 Year Warranty

1年保修

所有产品均有一年保修,请放心购买。

30 Day Money Back Guarantee

质量
保证

我们致力于设计和制造高于用户期望的数据采集(DAQ)产品。

Live Help