Personal Daq/50 Series

 

USB高分辨率数据采集模块

KEY HIGHLIGHTS

The Personal DAQ/50 Series multifunction USB data acquisition (DAQ) devices provide a higher-resolution than other Personal DAQ devices. Features include 22-bit resolution, analog voltage, frequency, or thermocouple input along with digital I/O, and counter/timer functions.

模拟输出
通道数 分辨率 最大采样率
多达20单端/10差分 22-位 80 S/s
采样 范围 隔离
复采样 ±20 V 至 ±31 mV 软件可选 500 V ch-host
模拟输出
通道数 分辨率 速度
数字I/O
通道数 计数器/定时器 编码器
多达 16 多达 4/—
软件 电源
操作系统支持 驱动 电源
Windows® DaqCOM™ 总线供电


Part Number Description Qty
Personal Daq/54 USB-based, 22-bit data acquisition module with 10 SE/5 DIFF inputs
Personal Daq/55 USB-based 22-Bit data acquisition module with 10 SE/5 DIFF Inputs, eight digital I/O, and two frequency/pulse inputs
Personal Daq/56 USB-based, 22-Bit data acquisition module with 20 SE/10 DIFF inputs, 16 digital I/O, and 4 frequency/pulse inputs
Signal Conditioning Options
PDQ1 Snap-on expansion module for the Personal Daq/50 Series, provides 20 volts/TC inputs and 16 digital I/O
    Data Sheet Data Sheet    User's Manual User Manual   
PDQ2 Snap-on expansion module for the Personal Daq/50 Series, provides 40 volts/TC inputs
    Data Sheet Data Sheet    User's Manual User Manual   
Accessories & Cables
CA-179-3 High-speed USB cable, 3 meter
CN-153-12 Terminal block for USB-1616HS Series and IOtech Personal Daqs
TR-2U External power supply, 90 to 264 VAC; requires additional cable, CA-1 (US) or CA-216 (European)
More Options...
CA-1 Required cable for use with TR-xx or PS-9V1AEPS-2500 power supplies; US version
CA-216 Required cable for use with TR-xx or PS-9V1AEPS-2500 power supplies; EU version
Thermocouples
745690-J001 J-type thermocouple wire, fiberglass (0 °C to 482 °C, 32 °F to 900 °F) 1 m
More Options...
745690-J002 J-type thermocouple wire, fiberglass (0 °C to 482 °C, 32 °F to 900 °F) 2 m
745690-K001 K-type thermocouple wire, fiberglass (0 °C to 482 °C, 32 °F to 900 °F) 1 m
745690-K002 K-type thermocouple wire, fiberglass (0 °C to 482 °C, 32 °F to 900 °F) 2 m
745690-T002 T-type thermocouple wire, fiberglass (0 °C to 260 °C, 32 °F to 500 °F) 2 m
Software
DASYLab® LITE DASYLab精简版提供所有驱动程序、不含分析功能、包含有限的模块数和1个布局窗口
More Options...
DASYLab® BASIC DASYLab普通版提供所有驱动程序、所有标准模块(不提供信号分析和操作模块)和1个布局窗口
DASYLab® FULL DASYLab完整版提供所有驱动程序、所有标准模块、200个布局窗口和控制定序器
DASYLab® PRO DASYLab专业版提供所有驱动程序、DASYLab完整版版本,以及所有附加模块(无第三方模块)
DASYLab® RUNTIME DASYLab Runtime允许您在另一台计算机上(硬件配置兼容)运行现有工作表应用程序
查看价格请先 录入信息创建账户

Product Reviews


4.7 / 5
Ease of Use
5 / 5
Value
4.3 / 5
Techincal Support
4.7 / 5

83% of new reviewers recommend this product


Personal Daq/54
May 22, 2017
Personal DAQ/56 and DASYLab

I used Personal DAQ's and Dasylab for many years. We had multiple setups for various tests that would be going on. It was our go to data acquisition system. I've started at a new company now and already have one unit and am waiting to order a second unit. Thanks.

  • Job Title: Senior Electrical Engineer
  • Industry: Aviation
  • Application: R&D testing.
  • From: Delaware
  • Company Size: 101-500
  • Software Used: DASYLab

  • Ease of use
  • Value
  • Techincal Support
Yes, I recommend this product!

Was this review helpful? Yes (2) / No (0)

Personal Daq/56
May 02, 2017
This product is our go-to method of analogue data acquisition

We have several of these in our facility. They connect easily and require minimum effort to begin data collection.

  • Job Title: Department Manager
  • Industry: Environmental Research
  • Application: Instrument data acquisition
  • From: RTP, NC
  • Company Size: 5000*
  • Software Used: Other

  • Ease of use
  • Value
  • Techincal Support
Yes, I recommend this product!

Was this review helpful? Yes (2) / No (0)

Personal Daq/54
April 11, 2016
Standard Data acqusition module for the Lab

This module added to the capacity previously purchased modules. We are very pleased with our previous modules and this one is the same except there are no digital outputs which we seldom use anyway. Standardizing on a data acquisition family results in equipment that has the same feel and similar options and is easier to set up and use in a particular application

  • Job Title: Sr Eng Tech
  • Industry: Industrial Controls
  • Application: measuring temperature and smoke density
  • From: Ashland, Ma 01721
  • Company Size: 101-500
  • Software Used: Other

  • Ease of use
  • Value
  • Techincal Support
Yes, I recommend this product!

Was this review helpful? Yes (1) / No (1)

Personal Daq/56
October 21, 2014
PDaq56

We have had wonderful success with the pDaq56 for our Data recording needs using DASYLab as our software. It has been a bread and butter for us for many years now for our wide range of recording needs in our CEMS field of environmental testing. Love the product and has been reliable. Only problems I have ever experienced before was a bit of lag time on delivery due to shortage of parts. Other than that great, product, great team.

  • Job Title: Shop Manager/Senior Tech
  • Industry: Environmental
  • Application: CEMS and other Data Recording
  • From: Wellington, OH 44090, USA
  • Company Size: 1-100
  • Software Used: DASYLab

  • Ease of use
  • Value
  • Techincal Support
Yes, I recommend this product!

Was this review helpful? Yes (1) / No (1)

Personal Daq/54
February 25, 2014
The product and service is OUTSTANDING!!!

We have been using measurement computing products for several years. We've used several A/D, D/A modules in our testers and lab. They're used extensively and stand up great! We recently ordered another A/D module and it arrived exactly on-time.

  • Job Title: Engineering Manager
  • Industry: Automotive
  • Application: Production testing, R&D
  • From: Laurinburg, NC, USA
  • Company Size: 1-100
  • Software Used: NI LabVIEW

  • Ease of use
  • Value
  • Techincal Support
Yes, I recommend this product!

Was this review helpful? Yes (2) / No (0)

Personal Daq/56
February 11, 2014
Durable and capable from 10 yr, multi unit user

We use our pdaq 56's in equipment that travels across the country and sees lots of bumps and extreme conditions. Besides the 56's channel capacity and its ability to take TC connections directly, the unit's durability is what has impressed us the most.

  • Job Title: Shop manager / test technician II
  • Industry: Environmental testing
  • Application: Stack testing
  • From: Indiana, USA
  • Company Size: 1-100
  • Software Used: DASYLab

  • Ease of use
  • Value
  • Techincal Support
Yes, I recommend this product!

Was this review helpful? Yes (2) / No (0)




The manual references "PDAQX.DLL", I am building a CSharp application to interface with the device and cannot find the DLL on your ftp server. What is the exact address? I'm probably being really stupid.

  • Job Title: Student
  • Industry: Computer Science
  • Application: Scientific Research
69 months ago
SomewhatAnon South Africa


Answers

Hello - There is no official support for C# or for that matter Visual BASIC dot net. However the folks in technical support created patched support and C# examples. For more information refer to the following article: http://kb.mccdaq.com/KnowledgebaseArticle50404.aspx

69 months ago
MeasurementComputing

Was this answer helpful? Yes (0) / No (0)

i have written some VB code to utilize a PDAQ/56. I'm only using 5 channels worth of input. Would I be able to purchase a PDAQ/54 and use the same code? Thanks, Jim

  • Job Title: Electrical Engineer
  • Industry: Aerospace
  • Application: Test and Measurement, Aircraft Fuel Monitoring Systems
73 months ago
JimMallabar Georgia, VT


Answers

Hi Jim - If all 5 input channels are analog (i.e. no counter or digital channels), then the same code will run OK. The Personal Daq/54 does not have digital or counter inputs.

73 months ago
MeasurementComputing

Was this answer helpful? Yes (0) / No (0)

I could not get a laptop with 64-bit Win7 to recognize the Daq/56, but it was recognized and connected when I installed it on a PC with 32-bit XP. I'd rather not have to reinstall Win7 on the laptop purchased for this project, if there's any driver for th

  • Job Title: Research Associate
  • Industry: Higher Ed
  • Application: Controlling a custom-built olfactometer via parallel port for ERP experiment
80 months ago
psyscott University of Missouri, Columbia, MO 65211, USA


Answers

Please feel free to contact us if you’re having any issues downloading software from our FTP site. Our Application Engineers are standing by and will be happy to get you up and running.

76 months ago
MeasurementComputing

Was this answer helpful? Yes (0) / No (0)

Yes...at least when using Dasy Lab. Try the Personaldaq 50 series found here. sometimes it takes several attempts ftp://ftp.mccdaq.com/downloads/iotech_software/

76 months ago
happydad50

Was this answer helpful? Yes (0) / No (0)

Yes, a Win7-64 compatible driver for this hardware series is available for download from our FTP site.

80 months ago
MeasurementComputing

Was this answer helpful? Yes (1) / No (0)

Included Software


  • Personal DaqView Out-of-the-Box Software for the Personal Daq/50 Series
  • PostView Time and Frequency Domain Post-Acquisition Data Viewing Software

Optional Software


  • DASYLab®2020 Software lets you interactively develop PC-based data acquisition applications by simply attaching functional icons

Product Manuals


Personal Daq/54
document
 
Personal Daq/55
document
 
Personal Daq/56
document
 

 

Quick Start Guide


DASYLab® LITE
QS-DASYLab-MCCDRV.pdf
 

 

 

 

Programming Example Downloads      download

Product Videos


MCC Video Library
video
 
1 Year Warranty

1年保修

所有产品均有一年保修,请放心购买。

30 Day Money Back Guarantee

质量
保证

我们致力于设计和制造高于用户期望的数据采集(DAQ)产品。

Live Help

在线帮助

不知道哪款产品最适合您的应用?我们的销售工程师会帮助您。