USB-1602HS 和 USB-1604HS 系列

 

高速BNC多功能器件

KEY HIGHLIGHTS

USB-1602HS和USB-1604HS系列高速USB数据采集设备提供同步模拟输入通道、数字I/O和计数器。每款设备均有3个正交编码器、两个定时器、两路模拟输出通道,同时各通道均有A/D。

模拟输入
通道数 分辨率 最大采样率
多达4路单端 16-位 高达2 Ms/s/ch
采样 范围 隔离
同步 ±10 V, ±2.5 V, ±500 mV 500 VDC ch-host
模拟输出
通道数 分辨率 速度
多达2路 16-位 高达1 MS/s
数字I/O
通道数 计数器/定时器 编码器
32 4/2 3
软件 电源
操作系统支持 驱动 电源
Windows® Universal Library™ SW Suite 外部


Part Number Description Qty
USB-1602HS 基于USB的16位、2 MS/s同步采样模拟输入器件
USB-1604HS 基于USB的16位、1.33 MS/s同步采样模拟输入器件
USB-1604HS-2AO 基于USB的16位、1.33 MS/s同步采样多功能DAQ器件
USB-1602HS-2AO 基于USB的16位、2 MS/s同步采样多功能DAQ器件
Accessories & Cables
CA-68-3R Cable, 68-conductor ribbon, 3 ft.
More Options...
PS-5V2AEPS Replacement power supply, 12-watt, for TC-32, USB-1602HS Series, USB-1604HS Series, USB-1608HS Series, USB-2416 Series, USB-3110, USB-3112, USB-3114, WEB-TEMP, WEB-TC - plugs available separately
More Options...
Australia Plug Australian interchangeable plug for power supplies
Europe Plug European interchangeable plug for power supplies
UK Plug UK interchangeable plug for power supplies
US Plug US interchangeable plug for power supplies
TB-102 Termination board with screw terminals
Software
DASYLab® LITE DASYLab精简版提供所有驱动程序、不含分析功能、包含有限的模块数和1个布局窗口
More Options...
DASYLab® BASIC DASYLab普通版提供所有驱动程序、所有标准模块(不提供信号分析和操作模块)和1个布局窗口
DASYLab® FULL DASYLab完整版提供所有驱动程序、所有标准模块、200个布局窗口和控制定序器
DASYLab® PRO DASYLab专业版提供所有驱动程序、DASYLab完整版版本,以及所有附加模块(无第三方模块)
DASYLab® RUNTIME DASYLab Runtime允许您在另一台计算机上(硬件配置兼容)运行现有工作表应用程序
TracerDAQ® Pro 开箱即用的虚拟仪器套件,集成带状图、示波器、函数发生器和速率发生器 – 专业版
查看价格请先 录入信息创建账户

Product Reviews


4.3 / 5
Ease of Use
4.7 / 5
Value
3.7 / 5
Techincal Support
4.5 / 5

100% of new reviewers recommend this product


USB-1604HS
April 11, 2016
This is an excellent High speed DAQ module

I used the USB-1604HS in a high speed analog aquisition application for vibration analysis. The simultaneous sampling of the analog input channels worked very well and provided the bandwidth we needed for my tests. This is a great 4 channel high speed module for a reasonable price.

  • Job Title: Controls Engineer
  • Industry: Automotive Safety
  • Application: Vibration Analysis
  • From: Ogden, Utah
  • Company Size: 5000*
  • Software Used: C++/C#/VB

  • Ease of use
  • Value
  • Techincal Support
Yes, I recommend this product!

Was this review helpful? Yes (0) / No (1)

USB-1602HS
July 20, 2015
Good product, needs more range.

This product is a good product but for the money it needs more range. The range is .5V, 2.5V, 5V, and 10V. But with 2023 I can get down to .2V which I used for my signal.

  • Job Title: Software Engineer
  • Industry:
  • Application:
  • From: Needham, MA
  • Company Size: 1-100
  • Software Used: C++/C#/VB

  • Ease of use
  • Value
  • Techincal Support
Yes, I recommend this product!

Was this review helpful? Yes (1) / No (0)

USB-1602HS-2AO
March 26, 2013
software improvement

It would be nice if the DAQ software can acquire data continuously, and let user choose each scan's number of samples and total number of samples.

  • Job Title: research assistant
  • From:
  • Company Size:
  • Software Used:

  • Ease of use
  • Value
  • Techincal Support
Yes, I recommend this product!

Was this review helpful? Yes (2) / No (0)




Can the USB-1602HS single ended analog inputs measure a signal on a 5Vdc common mode voltage, with the A/D return at 5V, due to the USB power isolation feature?

  • Job Title: Engineer
  • Industry:
  • Application:
5 months ago
Marc222 Alabama


Answers

We spec 500 VDC isolation between the USB bus and the DAQ I/O (but as soon as you connect one of the I/O to something that is not floating or isolated, then the DAQ becomes anchored. The analog common jack on the back of this DAQ family connects only to the BNC shells on its front … it does not connect to chassis/earth. This is where you would connect one low-side reference to serve both of your analog inputs (i.e. your anchor). In short, yes the unit can measure a signal riding on a 5Vdc common mode voltage, but you must be careful not to connect the BNC shells to any device that grounds its own BNC shell (i.e. at the other end of the cable) to earth. Also be careful (or don’t use) the digital I/O or counter I/O, since their ground will be anchored (indirectly) to your low-side reference potential.

5 months ago
Measurement Computing

Was this answer helpful? Yes (0) / No (0)

if i record a sampling of 10 second at 1M sampling rate with the ADC, can i output the same amount of point with the DAC during 10second. like 10M point

  • Job Title: technician
  • Industry: aerospace
  • Application: prototyping measurement
7 months ago
JohnShock canada


Answers

Yes, the USB-1602HS-2AO supports (2) 16 bit DACs with a per-channel update rate of 1 MS/sec. Your Windows buffer must be previously allocated and pre-loaded prior to the start of your AOutScan method.

7 months ago
Measurement Computing

Was this answer helpful? Yes (0) / No (1)

I have tried the ULAO02.py but it does not work (says board #0 not found or not compatible. When I run TracerDAQ or InstaCal both show the board #0 present and working.

  • Job Title: Engineer
  • Industry:
  • Application:
9 months ago
Sam California


Answers

Based on your report, we have confirmed that ULAO02.py is currently incompatible with the USB-1602HS-2AO hardware model. We will log that as a bug here. Instead we can refer you to the following 4 analog output examples which do run OK on this hardware model: v_out.py, a_out_scan.py, ULAO01.py, and DaqOutScan01.py.

9 months ago
Measurement Computing

Was this answer helpful? Yes (0) / No (0)

  • Job Title:
  • Industry:
  • Application:
62 months ago
Morris


Answers

Hello Morris - The input sensitivity for the USB-1602HS (when setup for the +-500 mV input range) is +- 0.000122 volts.

62 months ago
MeasurementComputing

Was this answer helpful? Yes (0) / No (0)

Hello, what is the impedance of the bnc connectors ? 50 ohm ?

  • Job Title: student
  • Industry:
  • Application:
46 months ago
mydu


Answers

The input impedance for the USB-1604HS series is typically 10 MΩ with the power on.

46 months ago
Measurement Computing

Was this answer helpful? Yes (0) / No (0)

I'm not sure I understood one of the answers listed. you've written that is can output 1MS/s - does this mean it has a buffer size of 16bit x 1MS = 16Mbit / 2MByte ?

  • Job Title: CTO
  • Industry: Consumer electronics
  • Application:
6 months ago
Yuval_Arcytec Israel


Answers

The USB-1604HS-2AO has a 1 Mbyte FIFO that is shared with the boards I/O subsystems. The analog output FIFO can hold up to 544288 samples. The previous answer is referring to a Windows buffer that you allocate from within your software program and preload with your waveform data.

6 months ago
Measurement Computing

Was this answer helpful? Yes (0) / No (0)

We are looking for a DAQ that can be used in a Linux based portable device. Do you have a C/C++ driver / example software for this device

  • Job Title: Electronics Engineer
  • Industry: Mining
  • Application: Measurement of vibration
75 months ago
GregJ Australia


Answers

Thank you for your inquiry. Unfortunately, the USB-1604HS-2AO is not currently supported under Linux. You may find a listing of the MCC products that have Linux support at: http://www.mccdaq.com/daq-software/Linux-Support.aspx. This list will be continuously updated as we continue to add Linux support to our data acquisition devices.

75 months ago
MeasurementComputing

Was this answer helpful? Yes (0) / No (0)

Included Software


  • TracerDAQ® for acquiring and displaying data and generating signals
  • InstaCalTM software utility for installing, configuration, and testing
  • Universal Library includes support for Visual Studio® and Visual Studio®.NET, including examples for Visual C++®, Visual C#®, and Visual Basic®.NET
  • ULx for NI LabVIEWTM Library of VIs and example programs to speed your NI LabVIEW development

Optional Software


  • DASYLab®2016 Software lets you interactively develop PC-based data acquisition applications by simply attaching functional icons
  • TracerDAQ®Pro - Out-of-the-box virtual instrument suite with strip chart, oscilloscope, function generator, and rate generator – professional version
  • MATLAB® Support for MCC Products - Software Environment for Data Acquisition, Data Analysis, and Application Development

Product Manuals


USB-1602HS
document
 
USB-1602HS-2AO
document
 
USB-1604HS
document
 
USB-1604HS-2AO
document
 

 

Quick Start Guide


DASYLab® LITE
QS-DASYLab-MCCDRV.pdf
 
ULx for NI LabVIEW™
QS ULx for NI LabVIEW.pdf
 

 

Product Videos


MCC Video Library
video
 

 

Programming Example Downloads      download

1 Year Warranty

1年保修

所有产品均有一年保修,请放心购买。

30 Day Money Back Guarantee

质量
保证

我们致力于设计和制造高于用户期望的数据采集(DAQ)产品。

Live Help

在线帮助

不知道哪款产品最适合您的应用?我们的销售工程师会帮助您。